About cookies on this site Our websites require some cookies to function properly (required). In addition, other cookies may be used with your consent to analyze site usage, improve the user experience and for advertising. For more information, please review your options. By visiting our website, you agree to our processing of information as described in IBM’sprivacy statement. To provide a smooth navigation, your cookie preferences will be shared across the IBM web domains listed here.
Publication
Zeitschrift fur Physik B-Condensed Matter
Paper
Atomic resolution in dynamic force microscopy across steps on Si(111)7 × 7
Abstract
In this note we report the first observation of salient features of the Si(111)7 × 7 reconstructed surface across monatomic steps by dynamic atomic force microscopy (AFM) in ultrahigh vacuum (UHV). Simultaneous measurements of the resonance frequency shift Δf of the Si-cantilever and of the mean tunneling current Īf from the cleaned Si tip indicate a restricted range for stable imaging with true atomic resolution. The corresponding characteristics vs. distance reveal why feedback control via Δf is problematic, whereas it is as successful as in conventional STM via Īt. © Springer-Verlag 1996.