About cookies on this site Our websites require some cookies to function properly (required). In addition, other cookies may be used with your consent to analyze site usage, improve the user experience and for advertising. For more information, please review your options. By visiting our website, you agree to our processing of information as described in IBM’sprivacy statement. To provide a smooth navigation, your cookie preferences will be shared across the IBM web domains listed here.
Publication
JPRAS Open
Paper
Advancing indocyanine green fluorescence flap perfusion assessment via near infrared signal quantification
Abstract
Introduction: Intraoperative indocyanine green fluorescence angiography (ICGFA) perfusion assessment has been demonstrated to reduce complications in reconstructive surgery. This study sought to advance ICGFA flap perfusion assessment via quantification methodologies. Method: Patients undergoing pedicled and free flap reconstruction were subjected to intraoperative ICGFA flap perfusion assessment using either an open or endoscopic system. Patient demographics, clinical impact of ICGFA and outcomes were documented. From the ICGFA recordings, fluorescence signal quality, as well as inflow/outflow milestones for the flap and surrounding (control) tissue were computationally quantified post hoc and compared on a region of interest (ROI) level. Further software development intended full flap quantification, metric computation and heatmap generation. Results: Fifteen patients underwent ICGFA assessment at reconstruction (8 head and neck, 6 breast and 1 perineum) including 10 free and 5 pedicled flaps. Visual ICGFA interpretation altered on-table management in 33.3% of cases, with flap edges trimmed in 4 and a re-anastomosis in 1 patient. One patient suffered post-operative flap dehiscence. Laparoscopic camera use proved feasible but recorded a lower quality signal than the open system. Using established and novel metrics, objective ICGFA signal ROI quantification permitted perfusion comparisons between the flap and surrounding tissue. Full flap assessment feasibility was demonstrated by computing all pixels and subsequent outputs summarisation as heatmaps. Conclusion: This trial demonstrated the feasibility and potential for ICGFA with operator based and quantitative flap perfusion assessment across several reconstructive applications. Further development and implementation of these computational methods requires technique and device standardisation.