About cookies on this site Our websites require some cookies to function properly (required). In addition, other cookies may be used with your consent to analyze site usage, improve the user experience and for advertising. For more information, please review your options. By visiting our website, you agree to our processing of information as described in IBM’sprivacy statement. To provide a smooth navigation, your cookie preferences will be shared across the IBM web domains listed here.
Publication
Applied Physics Letters
Paper
Thermal writing using a heated atomic force microscope tip
Abstract
Resistive heating of an atomic force microscope tip was used to perform thermally induced surface modifications. Heating was achieved by dissipating power in the legs of an electrically conducting silicon cantilever. Temperatures of up to 170°C were obtained using 40 mW of input power. Electrical measurements used to monitor the temperature showed thermal time constants of 0.35-0.45 ms, depending on whether the tip was in contact with a substrate. The heated tip was used to demonstrate thermomechanical writing on a polycarbonate substrate, as well as thermal writing of an optical phase change material. © 1996 American Institute of Physics.