About cookies on this site Our websites require some cookies to function properly (required). In addition, other cookies may be used with your consent to analyze site usage, improve the user experience and for advertising. For more information, please review your options. By visiting our website, you agree to our processing of information as described in IBM’sprivacy statement. To provide a smooth navigation, your cookie preferences will be shared across the IBM web domains listed here.
Publication
AIP Advances
Paper
The role of Mg interface layer in MgO magnetic tunnel junctions with CoFe and CoFeB electrodes
Abstract
The tunneling spin polarization (TSP) is directly measured from reactively sputter deposited crystalline MgO tunnel barriers with various CoFe(B) compositions using superconducting tunneling spectroscopy.We find that theMg interface layer thickness dependence of TSP values for CoFeB/Mg/MgO junctions is substantially different from those for CoFe/Mg/MgO especially in the pre-annealed samples due to the formation of boron oxide at the CoFeB/MgO interface. Annealing depletes boron at the interface thus requiring a finite Mg interface layer to prevent CoFeOx formation at the CoFeB/MgO interface so that the TSP values can be optimized by controlling Mg thickness. © 2012 Author(s).