About cookies on this site Our websites require some cookies to function properly (required). In addition, other cookies may be used with your consent to analyze site usage, improve the user experience and for advertising. For more information, please review your options. By visiting our website, you agree to our processing of information as described in IBM’sprivacy statement. To provide a smooth navigation, your cookie preferences will be shared across the IBM web domains listed here.
Publication
IRPS 2012
Conference paper
The effect of voltage bias stress on temperature-dependent conduction properties of low-k dielectrics
Abstract
The change in leakage current in porous low-k interconnect dielectrics (LKDs) arising from time-dependent dielectric breakdown (TDDB) has been investigated. Using periodic measurements of temperature-dependent IV curves and photocurrent decay during voltage bias stress the apparent change in trap density and conduction mechanism in LKDs are investigated. A substantial change in the temperature-dependence of the current is observed, suggesting a move from a thermally excited conduction process to a tunnel-like or percolative process. This change is correlated with a large increase in trap density after long-term bias stress, consistent with a trap to trap tunneling interpretation. However, throughout the high-voltage bias stress, the leakage current continues to obey a √E field dependence. © 2012 IEEE.